+48 794 626 676
Burner with a gas train

Ecostar Gazoram GRM gas burners.

Nozzle-mix process gas burners with a wide modulation range — for direct-fired furnaces, dryers and drying machines. Natural gas or LPG, 7 sizes, approx. 5–1,160 kW.

Gazoram (GRM) is a series of Ecostar process gas burners. Gas and air mix only at the burner nozzle (nozzle-mix), so the burner runs steadily across a wide power range — from a low flame to full load.

What the GRM burner looks like

Gazoram GRM 60 in the manufacturer's renderings. Click a picture to enlarge it.

Gazoram GRM 60 — flame tube side
Gazoram GRM 60 — flame tube side
Gazoram GRM 60 — gas train with valves and pressure switches
Gazoram GRM 60 — gas train with valves and pressure switches
Gazoram GRM 60 — fan above the burner body
Gazoram GRM 60 — fan above the burner body
Gazoram GRM 60 — damper actuator and gas train
Gazoram GRM 60 — damper actuator and gas train
Gazoram GRM 60 — rear view: fan, actuator and gas train
Gazoram GRM 60 — rear view: fan, actuator and gas train
Gazoram GRM 60 — front view: head and mounting flange
Gazoram GRM 60 — front view: head and mounting flange

Design and equipment

  • Fuel: natural gas or LPG, gas pressure upstream of the burner 21–50 mbar.
  • Nozzle-mix — a stable flame in furnaces and dryers with a stabilised combustion-chamber pressure.
  • Modulating output — a servomotor with mechanically linked air and gas dampers keeps the gas-to-air ratio right across the whole operating range.
  • Flame monitoring by ionisation, optionally by photocell.
  • Supplied complete: electromagnetic safety and operating valve, control relay, gas pressure switch, air pressure switch, manometer and ball valve.
  • Power supply 1N 230 V or 3N 400 V, 50 Hz. The burners are made to EN 746-2 (safety of industrial thermoprocessing equipment).

Models and outputs

Gazoram GRM according to manufacturer data (2026). Natural gas consumption at maximum output, calorific value 8,250 kcal/Nm³. GRM 15: minimum output approx. 5.2 kW (0.54 Nm³/h).
ModelMax. output [kW]Max. output [kcal/h]Max. natural gas consumption [Nm³/h]
GRM 15174.4150,00018.2
GRM 30348.8300,00036.4
GRM 40465.1400,00048.5
GRM 60639.5550,00066.7
GRM 70814.1700,00084.8
GRM 80872.1750,00090.9
GRM 1001,162.71,000,000121.2

Applications

  • Textile drying machines and stenters — also when converting from thermal oil or steam heating to gas.
  • Printing machines.
  • Drying and curing ovens.
  • Firing kilns.
  • Indirect air heating.
  • Food processing and baking.
  • Tempering and aluminium homogenising.

GRM or FPB?

We choose GRM for simpler gas installations up to approx. 1.2 MW. When oil or dual fuel, a higher operating temperature, more power (up to 5.8 MW) or a multi-burner system is needed, FPB process burners are the better choice.

What to prepare for an enquiry

  • Type of equipment and process: furnace, dryer, drying machine, required temperature.
  • Required output (kW or kcal/h) or the data from the nameplate of the existing burner.
  • Fuel (natural gas or LPG) and gas pressure upstream of the burner.
  • Combustion-chamber pressure and control method (e.g. temperature control, signal from the automation).
  • A few photos of the mounting point and the existing installation.
DocumentsWe provide the GRM manual and up-to-date technical data for the chosen model on request.

Send us the data from the boiler or furnace nameplate — we will size the burner.

Power, fuel, combustion chamber pressure. We reply within 48 hours, with no obligation.